Detachable front panel fits 19” racks with different depthsSupports RS-232 port and power outlet control (on/off) by outlet groupRemote and local power outlet control (On/Off, Power Cycle) by individual outlets and outlet groups...
Používame najnovšie technológie zabezpečenia obchodu, platieb a ochrany Vašich dát.
Tovar pochádza LEN od oficiálnych SK distribútorov!
To je zárukou lokalizácie a bezproblémovej reklamácie.
Garantujeme možnosť vrátenia tovaru nad rámec zákona.
Detachable front panel fits 19” racks with different depths Supports RS-232 port and power outlet control (on/off) by outlet group Remote and local power outlet control (On/Off, Power Cycle) by individual outlets and outlet groups Proactive Overload Protection (POP) – automatically powers off the last outlet that caused the current overload to protect high-end pro-A/V equipment and servers
Ideal for Pro-A/V applications, the ATEN NRGence™ PE6208AV eco PDUs are intelligent, 1U rack PDUs that contain 8 AC outlets available in an IEC socket configuration. The unique design with detachable front panel is convenient and mounts with different Pro-A/V equipment in 19” racks with different depths. In addition to remotely controlling individual outlets over the LAN, the front panel pushbuttons offer an extra option to control the outlets locally, allowing the flexibility to easily shutdown Pro-A/V equipment on the spot or from a remote location – for reduced power consumption. The outlets feature a sequential power-ON function that ensures Pro-A/V systems are powered on safely. Furthermore, compatibility with the ATEN Control System and Control4 libraries allow the PE6208AV to integrate with any Pro-A/V equipment for full control of all devices without complex programming.
The PE6208AV are optimal energy solutions for data centers as well. With the combination of ATEN eco PDUs and eco Sensors Energy Management software, a data center will be equipped with real-time monitoring, measurement, and analysis of energy consumption – with reports of power usage, PUE, RCI, and RTI to meet the ISO 50001 requirements. These indices reflect the data center’s energy usage and offer energy saving suggestions for optimizing energy use and reducing costs.
Connections Detachable front panel fits 19” racks with different depths Built-in 10/100 Mbit Ethernet Interface Supports TCP/IP, UDP, HTTP, HTTPS, SSL, DHCP, SMTP, ARP, NTP, DNS, Auto Sense, Ping, SNMP V1, V2, and V3, Telnet 2-level account/password security, IP/MAC filter, 128 bit SSL, RADIUS Browser access via IE, Firefox, Chrome, Safari, and more Easy integration with ATEN Control System and Control4 libraries Supports RS-232 port and power outlet control (on/off) by outlet group
Metering 1% Metering Accuracy – supports bank-level power metering Environment Monitoring – supports external temperature or temperature and humidity sensors for rack temperature and humidity monitoring
Outlet Switch Control Remote and local power outlet control (On/Off, Power Cycle) by individual outlets and outlet groups Multiple Power Control Methods – Wake on LAN, System After AC Back, Kill the Power Power-On Sequencing – users can set the power-on sequence and delay time for each outlet to allow equipment to be powered on in the correct order to enhance equipment safety Proactive Overload Protection (POP) – automatically powers off the last outlet that caused the current overload to protect high-end pro-A/V equipment and servers
eco Sensors Energy Management Software* Automatic discovery of all ATEN PDUs within the same intranet Remote real-time power measurement and monitoring of PDUs Real-time environment monitoring via sensors Plotting and monitoring of all ATEN PDU devices Exceed threshold alerts through real-time monitoring, SMTP, and System logs Power analysis reports
* eco Sensors is designed to work with NRGence™ eco PDUs and is bundled with all PE Series models.
Package Contents 1x PE6208AV Power Distribution Unit 1x Power Cord (exclude PE6208AVX) 1x RJ-45 Cable 1x Cable Ties 1x Footpad Set 1x Mounting Kit 1x User Instructions
Spínané a měřené PDU pro vzdálený power management over IP , 8 zásuvek C13 / 16A , připojovací zásuvka C20.
Měření spotřeby energie na úrovni PDU nebo zásuvky
Power Distribution Unit
* 8 outlets
* 20A (UL derated 16A) / 16A
* Outle...
Upgradeable Switched Unit Level Monitored EC rPDUs provide reliable power distribution to critical IT equipment while delivering individual outlet level control and a comprehensive view of input power usage via remote network access. Includ...
Upgradeable Switched Unit Level Monitored EC rPDUs provide reliable power distribution to critical IT equipment while delivering individual outlet level control and a comprehensive view of input power usage via remote network access. Includ...
Upgradeable Unit Level EC Monitored rPDUs provide reliable power distribution to critical IT equipment while delivering a comprehensive view of input level power usage via remote network access. Includes environmental monitoring capabilitie...